Jump to content
This site uses cookies. Continued use is acceptance of our Terms of Use and Privacy Policy. More Info... ×
  • Welcome to Celiac.com!

    You have found your celiac tribe! Join us and ask questions in our forum, share your story, and connect with others.




  • Celiac.com Sponsor (A1):



    Celiac.com Sponsor (A1-M):


  • Get Celiac.com Updates:
    Support Celiac.com!
    eNewsletter
    Donate
  • Record is Archived

    This article is now archived and is closed to further replies.

    Scott Adams
    Scott Adams

    Reevaluation of Duodenal Endoscopic Markers in the Diagnosis of Celiac Disease

    Reviewed and edited by a celiac disease expert.

    Bardella MT, Minoli G, Radaelli F, Quatrini M, Bianchi PA, Conte D Gastrointest Endosc. 2000 Jun;51(6):714-716

    Celiac.com Sponsor (A12):
    Background: Loss or reduction of duodenal folds, scalloping of Kerkring folds and a micronodular or mosaic duodenal mucosal pattern have been described in celiac disease (celiac disease), endoscopic findings that are considered reliable in the diagnosis of this disorder. However, most data have been obtained in patients with suspected or certain disease. We assessed the accuracy of the above markers in diagnosing celiac disease in patients with non-ulcer dyspepsia. Methods: In this prospective study, in 705 consecutive dyspeptic patients (284 men, 421 women, mean age 51 +/- SD 15.8 years) duodenal biopsies were obtained only in the presence of typical endoscopic markers, whereas in another 517 (207 men, 310 women, mean age 49.9 +/- SD 16 years) duodenal biopsies were done irrespective of macroscopic findings. celiac disease was diagnosed histologically and on the basis of positive antiendomysium antibody.

    Results: Endoscopic markers were found in 4 patients of the first group but celiac disease was ruled out. In the second group 5 patients had an endoscopic pattern that was consistent and celiac disease was diagnosed in 3, whereas 3 others with normal endoscopic findings were eventually diagnosed as having celiac disease. Endoscopic markers had a sensitivity of 50% and a specificity of 99.6% (95% CI [11.8, 88.2 and 98.6, 99.9], respectively) with positive and negative predictive values of 60% and 99.4%, respectively.

    Conclusion: The accuracy of endoscopic markers in the diagnosis of celiac disease must be reevaluated in relation to the characteristics of the population studied.



    User Feedback

    Recommended Comments

    There are no comments to display.



    Guest
    This is now closed for further comments

  • Get Celiac.com Updates:
    Support Celiac.com:
    Donate
  • About Me

    Scott Adams

    Scott Adams was diagnosed with celiac disease in 1994, and, due to the nearly total lack of information available at that time, was forced to become an expert on the disease in order to recover. In 1995 he launched the site that later became Celiac.com to help as many people as possible with celiac disease get diagnosed so they can begin to live happy, healthy gluten-free lives.  He is co-author of the book Cereal Killers, and founder and publisher of the (formerly paper) newsletter Journal of Gluten Sensitivity. In 1998 he founded The Gluten-Free Mall which he sold in 2014. Celiac.com does not sell any products, and is 100% advertiser supported.


  • Celiac.com Sponsor (A17):
    Celiac.com Sponsor (A17):





    Celiac.com Sponsors (A17-M):




  • Related Articles

    Jefferson Adams
    Celiac.com 05/21/2012 - A trio of researchers recently compared duodenal and jejunal small intestinal biopsies for diagnosis and follow-up of celiac disease. The researchers included J.W. Meijer, P.J. Wahab, and C.J. Mulder from the Department of Pathology, Rijnstate Hospital Arnhem, The Netherlands.
    Current pediatric guidelines advise doctors to take intestinal mucosal specimens from the jejunum using a suction capsule.
    This method can be stressful for patients, time-consuming, expensive and requires the use of imaging technology.
    Taking mucosal biopsies from the distal duodenum using forceps is less stressful for patients, easier, cheaper and can be done using an endoscope.
    For those reasons, the researchers wanted to compare the histological results of biopsies taken from...


  • Recent Activity

    1. - plumbago replied to Suzi374's topic in Celiac Disease Pre-Diagnosis, Testing & Symptoms
      3

      Lots of tests

    2. - trents replied to Suzi374's topic in Celiac Disease Pre-Diagnosis, Testing & Symptoms
      3

      Lots of tests

    3. - Suzi374 replied to Suzi374's topic in Celiac Disease Pre-Diagnosis, Testing & Symptoms
      3

      Lots of tests

    4. - Suzi374 posted a topic in Celiac Disease Pre-Diagnosis, Testing & Symptoms
      3

      Lots of tests

    5. - Peace lily posted a topic in Celiac Disease Pre-Diagnosis, Testing & Symptoms
      0

      Would like to gain weight


  • Celiac.com Sponsor (A19):



  • Member Statistics

    • Total Members
      121,224
    • Most Online (within 30 mins)
      7,748

    Suzi374
    Newest Member
    Suzi374
    Joined

  • Celiac.com Sponsor (A20):


  • Forum Statistics

    • Total Topics
      120.3k
    • Total Posts
      1m

  • Celiac.com Sponsor (A22):





  • Celiac.com Sponsor (A21):



  • Popular Now

    • Kmd2024
      5
    • Nicola flaherty
      4
    • ItchyHell
      4
    • MMH13
      20
    • Moodiefoodie
  • Popular Articles

    • Scott Adams
    • Scott Adams
    • Scott Adams
    • Scott Adams
    • Scott Adams
  • Upcoming Events

×
×
  • Create New...